AirFit P30i

AirFit P30i

Tube-up nasal pillows CPAP mask

AirFit P30i

Tube-up nasal pillows CPAP mask

  • Most preferred of its kind for treating sleep apnea1
  • Designed to give you more freedom
  • 80% quieter than the market-leading mask2-3*
  • SpringFit frame provides a stable, personalized fit
close-icon

Sleep the way you want

ResMed AirFit™ P30i is designed to keep air tubing out of sight and out of the way so you can sleep comfortably in your favorite position and get closer to your bed partner. Both of you will also enjoy more peace and quiet at bedtime, thanks to ResMed QuietAir™ vent technology – a mask feature designed to break up exhaled air for a quieter and gentler airflow.*

Sleep the way you want

ResMed AirFit™ P30i is designed to keep air tubing out of sight and out of the way so you can sleep comfortably in your favorite position and get closer to your bed partner. Both of you will also enjoy more peace and quiet at bedtime, thanks to ResMed QuietAir™ vent technology – a mask feature designed to break up exhaled air for a quieter and gentler airflow.*

Simplify your bedtime routine

AirFit P30i is designed to slide quickly on and off. In fact, twice as many CPAP users find that AirFit P30i is easier to use than the market-leading mask!1 If you need to get up at night, its quick-release elbow allows you to easily disconnect from therapy without the mask parts getting stuck or lost.

Simplify your bedtime routine

AirFit P30i is designed to slide quickly on and off. In fact, twice as many CPAP users find that AirFit P30i is easier to use than the market-leading mask!1 If you need to get up at night, its quick-release elbow allows you to easily disconnect from therapy without the mask parts getting stuck or lost.

Proven performance

Get the most out of CPAP therapy with AirFit P30i, a mask that seals securely, yet comfortably under the delicate nose area. In fact, nearly 80% of CPAP users find it provides them with an excellent seal.4†

To ensure you get an excellent seal, make sure you choose a well-fitted nasal pillows cushion for your AirFit P30i from one of our starter pack options – standard or small.

Proven performance

Get the most out of CPAP therapy with AirFit P30i, a mask that seals securely, yet comfortably under the delicate nose area. In fact, nearly 80% of CPAP users find it provides them with an excellent seal.4†

To ensure you get an excellent seal, make sure you choose a well-fitted nasal pillows cushion for your AirFit P30i from one of our starter pack options – standard or small.

Explore

left-rotate right-rotate

Support

Choosing the right frame size

  1. If you are male, start with the Standard frame. If you are female, start with the Small frame.
  2. If you try the Small frame, and it falls forward on your head or rests too close too your eyes, size up to the Standard frame for a better fit. 
  3. If the Standard frame falls back over your head or rests too close to your ears, try the Small frame for a more comfortable fit.

Getting started with therapy
Here are some links to help you get on the right track with the sleep therapy.

Your therapy basics

The how, what, where and why

The benefits of therapy

What does therapy do for you

Think positive

Some helpful tips

Mask assembly/reassembly

  1. Ensure you have all the mask parts together to begin.
  2. Connect the mask elbow to the frame.
  3. Thread the left end of the headgear into the left side of the frame and fasten the tab. Next, thread the right end of the headgear into the right side of the frame and fasten the tab.
  4. Align the arrow on the nasal pillow cushion to the arrow on the frame and connect them together. Then, connect the remaining end of the nasal pillow cushion and frame together with the ResMed logo facing the right way up through the headgear.

Mask fitting

  1. Bring the mask above your head and then down over your face while ensuring the elbow is centered on top of the head.
  2. Place the headgear behind the head and align the nasal pillows into your nostrils. 
  3. Adjust the headgear by tightening or loosening it as appropriate until the mask and nasal pillows cushion are comfortably in place.
  4. Squeeze the side buttons on both sides of the mask elbow to quickly and easily disconnect it from the top of the frame, and then attach it to your air tubing.
  5. Reconnect the mask elbow (with the air tubing connected) to the top of the frame.

Mask disassembly

  1. Ensure the mask is disconnected from the CPAP machine.
  2. Pull the nasal pillows cushion out from one end of the frame. Repeat on the other end.
  3. Unfasten the headgear tab from one side and pull it out of the frame. Repeat on the other side. 
  4. Squeeze the side buttons on the mask elbow and pull up to quickly and easily release it from the frame.

Vent connection

  1. To disconnect the vent, gently pull the nasal pillows piece away and slide the vent out.
  2. To reconnect the vent, align the notch on the nasal pillows piece with the groove on the vent, and then gently pull the nasal pillows piece over the vent.

Getting started with therapy
Here are some links to help you get on the right track with the sleep therapy.

Your therapy basics

The how, what, where and why

The benefits of therapy

What does therapy do for you

Think positive

Some helpful tips

Managing mask leak

  1. Locate where the air is escaping from on your mask, which is typically above or below the nasal pillows cushion.
  2. If air leaks from the side or top of the cushion, adjust the mask fitting to improve the seal.
  3. Gently pull the nasal pillows cushion out from under the nose and away from the face. Then, let the mask reseal itself.
  4. Adjust the headgear as needed to achieve a more secure seal. Then, check to ensure the frame is secure and that the mask elbow and air tubing are not pulling on the mask.

Daily cleaning

  1. Take the nasal pillows cushion off of the frame as per disassembly instructions.
  2. Soak the nasal pillows cushion in warm water and a mild liquid detergent.
  3. Clean the nasal pillows cushion and its vent holes inside and out with a soft bristle brush.
  4. Rinse the nasal pillows cushion thoroughly under running tap water.
  5. Gently shake it to remove any excess water.
  6. Leave the nasal pillows cushion to air dry away from direct sunlight.

Weekly cleaning

  1. Disassemble the mask into its components as per disassembly instructions.
  2. Soak each of the mask components (headgear, elbow and frame) in warm water and a mild liquid detergent.
  3. Gently hand-wash the headgear. Clean the mask elbow and frame with a soft bristle brush.
  4. Rinse each of the mask components thoroughly under running tap water.
  5. Squeeze the headgear and the sleeves on the frame with a clean towel to remove excess water.
  6. Leave each of the mask components to air dry away from direct sunlight.

Mask inspection

  1. To maintain optimum therapy performance, check your mask regularly for visible signs of damage and/or deterioration, such as cracks, discoloration or tears.
  2. Check each mask part as it's cleaned.
  3. Inspect the headgear, frame, elbow, cushion and air tubing.
  4. Replace mask parts regularly to help prevent mask deterioration from occurring and help optimize mask performance.
  5. Recommended resupply schedule:
    - Nasal pillows cushion: 2 x per month
    - Air tubing: every 3 months
    - Headgear: every 6 months
    Note: Replacement cycles may vary depending on your insurance coverage. 
  6. The QuietAir vent* can be removed to allow inspection of the vent holes.
  7. A slight discoloration of the silicone cushion components may occur and is acceptable.
  8. If any mask component appears damaged or deteriorated, it should be discarded and replaced.
  9. Follow up with your equipment provider if you have questions.

Getting started with therapy
Here are some links to help you get on the right track with the sleep therapy.

Your therapy basics

The how, what, where and why

The benefits of therapy

What does therapy do for you

Think positive

Some helpful tips

Our ecosystem
Individual answers. Collective solutions.

At ResMed, innovation isn’t just an individual idea, it’s an integrated practice. Our innovative products are designed to work together to provide a more powerful solution for you and your patients.

References

* ResMed QuietAir™ diffused venting technology is a feature available in AirFit P30i retail mask systems only. This feature is not available in AirFit P30i sleep lab (SLM) mask systems

On a Likert scale of 0-10, 17 out of 22 CPAP users rated the AirFit P30i seal between 8 and 10

Combined responses of those expressing a preference in an independent patient survey in the USA, UK, Germany, France and Australia, from March 2017. Visit ResMed.com/MaskBrand


1. ResMed fitting study of 74 current CPAP users from June 4 to June 8, 2018 in multiple US locations who trialed ResMed AirFit P30i, Phillips™ Respironics DreamWear gel pillows or ResMed AirFit P10.

2. ResMed AirFit P30i combined user guide. Bella Vista, Australia; 2018.

3. Koninklijke Philips N.V. Philips Respironics DreamWear gel pillows instructions for use. Murrysville, PA; 2016.

4. ResMed guided external clinical study of 22 evaluable current nasal pillows mask users from May to June 2018 in Sydney, Australia who trialed ResMed AirFit P30i and Phillips Respironics DreamWear gel pillows.


DreamWear and Phillips are trademarks of Koninklijke Philips N.V, registered in the US and other countries.