Full-face mask
AirFit F20

360 View

Select model:

  • Innovative InfinitySeal silicone cushion designed to fit everyone, tolerate misfitting and accommodate patient movement
  • Comfortable and flexible frame designed to support the widest range of facial types
  • Easy to use magnetic clips for quick fitting
  • Clear field of vision for reading or watching TV in bed
  • Women’s variant (for Her) available for more tailored therapy

  • Patient tested and preferred

    Recent studies have shown that, when comparing against the current market-leading full-face mask, 86% of patients prefer the seal of AirFit F20.1

    In terms of stability and ease of use, the majority of patients studied also prefer AirFit F20 over the current market leader1, demonstrating that our technologies work to improve patient experiences. Through extensive studies, we have designed a Full-face mask to deliver superior therapy performance and a smoother, easier patient experience.

Explore

left-rotate right-rotate

Support

Sizing

  1. To comfortably fit a broader range of patients, AirFit F20 features an entirely new cushion design. To make crosswalking your existing patients easier, we recommend using our sizing guide – included in each AirFit F20 box and specifically designed to help patients find the right fit. You can also download a copy of our sizing guide here.
  2. The arrow of your sizing guide should align with the top of your patient’s nasal bridge. The segment of the guide corresponding with the crease below your patient’s lower lip will indicate their best fit. If a patient falls between sizes, we recommend selecting a larger option for greater comfort.
  3. AirFit F20 has three cushion sizes - small, medium and large. The modular design of the AirFit F20 means each size cushion easily clicks into the same mask frame.
  4. Your patients can also download a copy of our sizing guide from the ResMed website.

Fitting

  1. Unclip EasyClick Magnets.
  2. With your patient holding the mask towards their face, slide the headgear over the back of their head.
  3. Reclip EasyClick Magnets.
  4. Once your patient’s headgear and mask are properly fitted, you can use the upper and lower headgear straps to help fine-tune their fit. This is also a good opportunity for your patient to reseat their cushion for comfort. When fitting is concluded, the cushion membrane should be fitting comfortably over your patient’s nasal bridge.
  5. For additional information on mask maintenance and care, you can also visit the Supporting your patients section.

Fitting your AirFit F20

  1. Unclip the EasyClick Magnets.
  2. With the mask held against your face, pull the headgear over your head. Ensure the top of the mask cushion is sitting comfortably at the top of your nasal bridge. The bottom of your headgear should settle comfortably at the top of your neck - with the top of the headgear sitting on your crown.
  3. Bring each of the magnets up to meet their corresponding clips on the frame.
  4. Adjust the tabs on the upper headgear.
  5. Adjust the tabs on the lower headgear.
  6. With your device still switched off, connect your device tubing to your mask elbow.
  7. Connect the elbow to your mask.
  8. To ensure your fit will work with your therapy: Switch on your device and position yourself as if you are to begin therapy (e.g. lying down in bed). Adjust your upper straps. Adjust your lower straps. Practice reseating your cushion – pull your mask away from your face, allow your cushion to reinflate, and then resettle the inflated cushion so the cushion membrane is sitting at the top of your nasal bridge.

Managing leak with your AirFit F20

  1. Leak often occurs when your mask’s seal is compromised by movement, incorrect fitting or improper sizing.
  2. To find a source of leak, run your finger along the edge of your mask’s seal. Once located, adjust your headgear.
  3. Resolve any leak in the upper part of your mask by adjusting your upper straps.
  4. Resolve lower mask leak with your lower straps.
  5. If leak persists, reseal by briefly pulling your mask away from your face, letting your cushion reinflate, and resettling your mask cushion so the cushion membrane is sitting at the top of your nasal bridge.
  6. If leak continues, you may need a different size mask. Try our sizing guide or speak to your healthcare provider about getting a different size mask.

Cleaning your AirFit F20 (Daily)

  1. Disassemble mask.
  2. Rinse frame, elbow and cushion under running water. Clean each component with a soft brush.
  3. Soak components in warm water with mild liquid detergent for up to ten minutes.
  4. Shake components in water.
  5. Brush moving parts of elbow and around vent holes.
  6. Brush areas of frame where arms connect, and inside and outside the frame where the elbow connects.
  7. Rinse components under running water.
  8. Leave components to air dry out of direct sunlight – making sure to squeeze the arms of the frame to ensure excess water is removed.

Cleaning your AirFit F20 (Weekly)

  1. Disassemble mask. EasyClick magnets can remain attached to headgear during cleaning.
  2. Handwash headgear in warm water with mild liquid detergent.
  3. Rinse headgear under running water. Inspect to ensure headgear is clean and detergent free. Wash and rinse again, if necessary.
  4. Squeeze headgear to remove excess water.
  5. Leave headgear to air dry out of direct sunlight.

How to Reassemble

  1. Print your ResMed sizing guide. Remember to print to scale.
  2. Trim your guide from the paper.
  3. Using a mirror, hold your sizing guide to your face. The top of the guide should correspond with the highest part of tour nose bridge—just between your eyes.
  4. The lower part of the guide indicates which mask size is best for your face. The size that aligns just below your lower lip will be your best fit.

How to Disassemble

  1. Print your ResMed sizing guide. Remember to print to scale.
  2. Trim your guide from the paper.
  3. Using a mirror, hold your sizing guide to your face. The top of the guide should correspond with the highest part of tour nose bridge—just between your eyes.
  4. The lower part of the guide indicates which mask size is best for your face. The size that aligns just below your lower lip will be your best fit.

Haircare Tips for AirFit F20

Getting started with therapy
Get on the right track with your sleep tharapy.

Your therapy basics

The how, what, where and why…

The benefits of therapy

What does therapy do for your patient…

Think positive

Some helpful tips…

References

  1. ResMed internal study of 22 existing ResMed patients, conducted between 26/04/2016 – 27/05/2016 comparing the market leading mask with AirFit F20. Preliminary patient study – data on file.
  2. ResMed AirFit F20 internal fitting study of 27 ResMed and non-ResMed patients, conducted between 30/03/2016 – 04/04/2016. Preliminary patient study – data on file.
  3. ResMed AirFit F20 internal international fitting study of 34 ResMed and non-ResMed patients, conducted between 11/04/2016 – 15/04/2016. Preliminary patient study – data on file.
  4. ResMed AirFit F20 internal international fitting study of 90 ResMed and non-ResMed patients, conducted between 06/06/2016 – 22/06/2016. Preliminary patient study – data on file.

Still have a question?