Helpful resources
For additional therapy assistance.
Documents
Setting up your machine
Adding optional humidification
(for AirFit N20 or AirFit P10 for AirMini only):
Connecting your machine and smart device
Authenticating your device
Starting therapy on the Sleep screen
Adjusting comfort settings
The Dashboard
The design of AirMini is to support both simplicity and a richer experience depending on your preference. To support this, we designed AirMini with a simple one-button interaction for simplicity and an accompanying app to unlock a richer, more engaging therapy experience.
If the smart device disconnects for any reason, the AirMini will continue to deliver therapy uninterrupted. The data will be transmitted to your smart device when it next connects to the machine.
Your smart device should automatically reconnect to the AirMini machine after you have successfully paired once; assuming Bluetooth® is activated and visible on your smart device. However, you can also connect by simply tapping the Bluetooth® icon on the top right corner of the app’s home screen. A prompt to connect your smart device with the AirMini machine will appear. The Bluetooth® icon will be visible in the app and the Bluetooth® LED on the machine will turn blue and remain blue when paired with your smart device and AirMini machine.
Sleep score and sleep statistics is viewable in the AirMini App. AirView support will come online soon and clinicians will be able to view night profile data in AirView.
The ActiveAir and HumidX technology are new technologies that have only been implemented for AirMini. As a result the 20 series masks and AirFit P10 for AirMini are the only masks designed to work with the new AirMini system, therefore no other masks are compatible with the AirMini machine.
No. The HumidX cannot be cleaned and should be replaced 30 days after opening the packaging.
ResMed does not recommend the HumidX to be used beyond 30 days. If the HumidX is used beyond 30 days this can cause deterioration in cleanliness, humidification performance and breathing comfort which can affect safe and efficacious use of AirMini. Ensure the HumidX and other components of the AirMini system are regularly maintained as per the user instructions.
Yes, the design of the AirMini machine accepts an AC input range of 100-240V and a DC output of 24V. However, purchasing the correct AirMini power supply unit for the country you are visiting is recommended to ensure correct performance of your AirMini machine. Contact your care provider for more information.
AirMini’s optimal performance temperature range is between 5°C to 35°C (41°F to 95°F). The operating temperature range is similar to that of the AirSense 10 machine. Optimal performance of the AirMini machine’s performance cannot be guaranteed if operated outside the recommended temperature range.
The Sleep screen displays current pressure in real-time. The sleep dashboard shows your sleep report and the progression of therapy. Sleep data and therapy score can be accessed from the Dashboard screen once therapy is complete.
Daily cleaning
For N20 users
Note: Do not wash or wet the HumidX / HumidX Plus. When not in use, store in a clean and dry place.
For F20 users
For P10 for AirMini users
Weekly cleaning
AirMini tubing
Disassembly
For N20 users
For F20 users
For P10 users
AirMini
The design of AirMini is to support both simplicity and a richer experience depending on your preference. To support this, we designed AirMini with a simple one-button interaction for simplicity and an accompanying app to unlock a richer, more engaging therapy experience.
If the smart device disconnects for any reason, the AirMini will continue to deliver therapy uninterrupted. The data will be transmitted to your smart device when it next connects to the machine.
The optional HumidX technology is integrated in the AirMini tubing and allows exhaled air to pass through the HumidX before reaching the mask vent. This configuration captures the heat and moisture from the air and returns it to the patient upon inhalation. The operation of the HumidX mimics the natural humidification processes of the nose to boost moisture levels when using CPAP therapy. The ability to capture the patient’s exhaled moisture before exiting the mask vent is designed to provide an increased usability and breathing comfort.
Sleep score and sleep statistics is viewable in the AirMini App. AirView support will come online soon and clinicians will be able to view night profile data in AirView.
The ActiveAir and HumidX technology are new technologies that have only been implemented for AirMini. As a result the 20 series masks and AirFit P10 for AirMini are the only masks designed to work with the new AirMini system, therefore no other masks are compatible with the AirMini machine.
No. The HumidX cannot be cleaned and should be replaced 30 days after opening the packaging.
ResMed does not recommend the HumidX to be used beyond 30 days. If the HumidX is used beyond 30 days this can cause deterioration in cleanliness, humidification performance and breathing comfort which can affect safe and efficacious use of AirMini. Ensure the HumidX and other components of the AirMini system are regularly maintained as per the user instructions.
Yes, the design of the AirMini machine accepts an AC input range of 100-240V and a DC output of 24V. However, purchasing the correct AirMini power supply unit for the country you are visiting is recommended to ensure correct performance of your AirMini machine. Contact your care provider for more information.
AirMini’s optimal performance temperature range is between 5°C to 35°C (41°F to 95°F).The operating temperature range is similar to that of the AirSense 10 machine. Optimal performance of the AirMini machine’s performance cannot be guaranteed if operated outside the recommended temperature range.
The Sleep screen displays current pressure in real-time. The sleep dashboard shows your sleep report and the progression of therapy.Sleep data and therapy score can be accessed from the Dashboard screen once therapy is complete.
Inspection and replenishment
For F20 users
For N20 users
AirMini tubing
AirMini air filter
HumidX and HumidX Plus
Humidification
The design of AirMini is to support both simplicity and a richer experience depending on your preference. To support this, we designed AirMini with a simple one-button interaction for simplicity and an accompanying app to unlock a richer, more engaging therapy experience.
If the smart device disconnects for any reason, the AirMini will continue to deliver therapy uninterrupted. The data will be transmitted to your smart device when it next connects to the machine.
The optional HumidX technology is integrated in the AirMini tubing and allows exhaled air to pass through the HumidX before reaching the mask vent. This configuration captures the heat and moisture from the air and returns it to the patient upon inhalation. The operation of the HumidX mimics the natural humidification processes of the nose to boost moisture levels when using CPAP therapy. The ability to capture the patient’s exhaled moisture before exiting the mask vent is designed to provide an increased usability and breathing comfort.
Sleep score and sleep statistics is viewable in the AirMini App. AirView support will come online soon and clinicians will be able to view night profile data in AirView.
The ActiveAir and HumidX technology are new technologies that have only been implemented for AirMini. As a result the 20 series masks and AirFit P10 for AirMini are the only masks designed to work with the new AirMini system, therefore no other masks are compatible with the AirMini machine.
No. The HumidX cannot be cleaned and should be replaced 30 days after opening the packaging.
ResMed does not recommend the HumidX to be used beyond 30 days. If the HumidX is used beyond 30 days this can cause deterioration in cleanliness, humidification performance and breathing comfort which can affect safe and efficacious use of AirMini. Ensure the HumidX and other components of the AirMini system are regularly maintained as per the user instructions.
Yes, the design of the AirMini machine accepts an AC input range of 100-240V and a DC output of 24V. However, purchasing the correct AirMini power supply unit for the country you are visiting is recommended to ensure correct performance of your AirMini machine. Contact your care provider for more information.
AirMini’s optimal performance temperature range is between 5°C to 35°C (41°F to 95°F).The operating temperature range is similar to that of the AirSense 10 machine. Optimal performance of the AirMini machine’s performance cannot be guaranteed if operated outside the recommended temperature range.
The Sleep screen displays current pressure in real-time. The sleep dashboard shows your sleep report and the progression of therapy.Sleep data and therapy score can be accessed from the Dashboard screen once therapy is complete.
Still have a question?